• Hydraulic test: industrial facilities are gradually pressurized through a pressurization system, with a test pressure of up to 170MPa, to determine the integrity of the industrial facility by testing the drop in system pressure during the design time and the leakage of the test fluid.
• Airtightness testing: Provide customized airtightness testing solutions according to specific customer needs and equipment characteristics.
• Helium leak testing: Provide a variety of helium leak testing methods, such as vacuum method, suction gun method, helium mask method, helium spray method, etc., and the measurement accuracy can reach 1.0×10-10 mbar·L/s.